Views: 2447

Gas Monitors INNOVA 1512

Product code : 1662369467

Advanced Energy's Innova 1512 is based on the photoacoustic infrared spectroscopy and delivers superior sensitivity in a very compact form factor. Extremely versatile by design, the 1512 is capable of measuring almost any gas that absorbs infrared light. Leverages the unique strengths of the photoacoustic sensor technique User-friendly, stable, reliable, and highly accurate Extremely low-volume flushing possible

Quantity:
More information:
  • Nhà Sản Xuât
  • Advanced Energy Inc.

    Typical Applications

    • Measurement of refrigerant emissions from mobile A/C systems
    • Animal husbandry
    • Soil science
    • Fumigant monitoring
    • Contaminated soil
    • Ventilation performance
    • Industrial hygiene-IAQ monitoring
    • Waste anesthesia monitoring
    • Biogas analysis
    • Sorbent gas filter testing
    • Photocatalytic material testing
    • Research and development
    • SF6 leak testing
    Specification:
    Detection Limit Gas dependent, but typically in the ppb region; using the Gas Detection Limits Chart, the detection limit for a selected sample integration time (SIT) can be calculated
    Dynamic Range Typically four orders of magnitude (i.e., 10,000 times the detection limit at 5 SIT); using two span concentrations it can be expanded to five orders of magnitude
    Repeatability 1% of measured value
    Measured at 20°C, 1013 mbar, and relative humidity (RH): 60%; a concentration of 100x detection limit (5s SIT) was used in determining these specifications
    Interference The 1512 automatically compensates for temperature and pressure fluctuations in its analysis cell and can compensate for water vapor in the air sample; if an optical filter is installed to measure a known interferent, the 1512 can cross compensate for the interferent
    Internal Data Storage Capacity The total space available in display memory to store data ia 131072 measurement cycles; if a measurement cycle takes 15 sec, then the display Memory space will be sufficient for a 22-day monitoring task
    Operating Temperature 5 to 40°C (41 to 104°F)
    Humidity Maximum relative humidity: 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
    Enclosure IP 20
    H x W x D 195 x 443 x 244 mm (7.68 x 17.44 x 9.60 in)
    Weight 11 kg (24.3 lb)
    Pumping Rate 30 cm3/s (flushing sampling tube) and 5 cm3/s (flushing measurement chamber)
    Air Volume Per Sample See data sheet
    Total Internal Volume 60 cm3 (of the measurement system)
    Power Ratings ~85 VA, 100 to 240 VAC ±10%, 50 to 60 Hz, Class 1
    Alarm Relay Socket For connection to one or two alarm relays (visual / audio)
    Alarm levels for each gas are user-defined
    System on / running status available
    Maximum 25 VDC, maximum 100 mA
    Back-Up Battery 3 V lithium battery, lifetime 5 years; this protects data stored in memory and powers the internal clock
    Monitor Interface Three interfaces: USB, Ethernet, and RS232, for data exchange and remote control of the instrument
    Software Communication Via USB, Ethernet, or RS232 interface