Views: 5037

CI-710s SpectraVue Leaf Spectrometer

Product code : 1489637343

The SpectraVue Leaf Spectrometer measures transmission, absorption, and reflection, along with many other plant stress and pigment indicators using built-in indices. Measure the effects of environmental variables on nutrient and pigment quantification and use chemometric modeling to optimize plant health and yield. Leaf spectral data in response to stressors can drive a wide variety of insights into forest health and management practices. Use spectral analysis to conduct non-destructive assays of physiological responses to different environmental conditions.

Quantity:
More information:
  • Nhà Sản Xuât
  • CID Bio-Sciencie

    Specifications
    • Dimension 220 mm x 150 mm x 30 mm
    • Weight 952 g
    • Operating Environment -30° to 70° C storage, -10° to 50° C Operation,
    • 0% – 90% noncondensing humidity
    • Minimum Leaf Size 20 mm x 20 mm
    • Display 7” 1024 x 600 IPS Display
    • Languages English, Spanish
    • Measure modes Reflectance, Transmittance and Absorbance
    Detector Specifications
    • Detector CMOS Linear Array
    • Wavelength Range 360 – 1100 nm
    • Pixels 2048 pixels
    • Pixel Size 14 μm x 200 μm
    • Pixel Well Depth 100,000 electrons
    • Signal-To-Noise Ratio 330:1 (at full signal)
    • A/D Resolution 16 bit
    • Dark Noise 16 counts
    • Corrected Linearity >99.8%
    • Sensitivity 337.500
    • Wavelength Data Increment 0.55 – 0.7 nm
    Spectroscopic
    • Grating 300 lines/mm, Slit = 55 μm
    • Optical Resolution 2.4 FWHM in nm
    • Integration Time 30 μs – 60 seconds
    • Dynamic Range 3300:1
    • Stray Light 0.2 – 1.0%
    Electronics
    • Power Supply Two 18650 batteries and USB-C
    • Battery life 3 – 4 hours
    • Trigger Modes Automatic & Manual
    Theory of operation
    SPECTRAVUE is a powerful spectrometer paired with a leaf probe attachment, on-board operating software, and display screen. Two broadband light sources are attached inside the device. One is positioned in the leaf clamp for transmissive measurements, and one is placed inside the case for reflective measurements. The spectrometer module takes the light from the leaf probe attachment and projects the wavelength dispersed light onto a CCD array. Each pixel of the CCD array thus corresponds to a specific wavelength of light. The operating software displays the light intensity of each pixel of the CCD array.
     
    Three spectroscopic measurements can be performed by SPECTRAVUE:
     
    Transmittance (T) is the fraction of the incident light passing through a sample, such as a leaf. When the intensity of the incident light is Io, and the intensity of light passing through the sample is It, the transmittance, T, is then expressed as T = It / Io. The CI-710s software suite can automatically calculate and plot the transmission spectrum with the reference spectrum (the intensity profile of the light source) stored.
     
    Absorbance (A) is related to the transmittance as A = – log T = -log(It / Io). Absorbance is commonly denoted in optical density (OD) as it is linearly proportional to the amount of light absorbing sample in the light path length (Beer-Lambert law). For example, in a standard 1-cm cuvette, a sample with an OD of 2 is twice as concentrated as a sample with an OD of 1. But note that the intensity of light transmitted from a sample with an OD of 2 is only 1/10 of that from a sample with an OD of 1. Transmission and absorption spectrum measurements are the most common applications of spectrometers. The spectrum can be used for the quantification of chemical concentrations, color analysis, the study of photochemical reactions such as photosynthesis, and the quantification of physical or optical properties such as film thickness, index of refraction, and extinction coefficient.
     
    Reflectivity (R) is the fraction of incident light that is reflected from a sample. Depending on the purposes of the study, reflectivity can be measured for reflection at a specific angle from the sample, or the entire reflected hemisphere. The leaf probe attachment of CI-710s is not designed to measure the directional reflectivity. Nonetheless, it can be used to measure the absorption spectrum of surface substance of reflective or opaque samples.

Related Products

Updating
VIDEO
Lingerie Fashion