Frequency
• High Band: 100 kHz-1 MHz
• Low Band: 10 kHz-50 kHz
Output Power
• High: 100 kHz – 500 W RMS max
200 kHz – 400 W RMS max, 750
kHz – 200 W RMS max
• Low: 12 kHz – 1kW RMS max, 50
kHz – 750 W RMS max
• Very Low: 3kHz – 4kW (transducer
impedance dependant)
Input Power
• 110 or 220 V AC or 24 VDC 50
watts
Resolution
• 0.01m / 0.1 ft.
Accuracy
• 0.01m / 0.10 ft. +/- 0.1% of depth @
200 kHz
• 0.10m / 0.30 ft. +/- 0.1% of depth @
33 kHz
Depth Range
• 0.2 – 200m / 0.5 – 600 ft. @ 200
kHz
• 0.5 – 1500m / 1.5 – 4500 ft. @ 33
kHz
Chart Scales
• 5,10,20,40,80,100,200,400,800,
1600 m
• 15,30,60,120,240,300,600,1200,
2400,4800 ft.
Phasing
• Automatic scale change, 10%,20%,
30% overlap or Manual
Sound Velocity
• 1370 – 1700 m/s |
• Resolution 1 m/s
Transducer Draft Setting
• 0 – 15m (0 – 50 ft.)
Depth Display
• On control PC.
Clock
• Internal battery backed time,
elapsed time, and date clock
Annotation
• Internal – date, time, GPS position
• External – from RS232 port or
Ethernet.
Interfaces
• 2 x RS232 serial ports, baud rate
selectable 4800-19200.
• Inputs from external computer,
motion sensor, sound velocity.
• Outputs to external computer
• Ethernet interface
• Heave – TSS1 and sounder
sentence
Blanking
• 0 to full scale
Software
• Echotrac Control supplied
• ChartView display and logging
software
Help
The function of each parameter and it’s
minimum and maximum values can be
displayed.
Environmental Operating Conditions
• 0°– 50° C, 5 – 90% relative
humidity, Non-condensing
Dimensions
• 53 cm (20.75”) H x 44cm (17.25”)
W x 21.5cm (8.5”) D |