| Frequency • High Band: 100 kHz-1 MHz
 • Low Band: 10 kHz-50 kHz
 Output Power
 • High: 100 kHz – 500 W RMS max
 200 kHz – 400 W RMS max, 750
 kHz – 200 W RMS max
 • Low: 12 kHz – 1kW RMS max, 50
 kHz – 750 W RMS max
 • Very Low: 3kHz – 4kW (transducer
 impedance dependant)
 Input Power
 • 110 or 220 V AC or 24 VDC 50
 watts
 Resolution
 • 0.01m / 0.1 ft.
 Accuracy
 • 0.01m / 0.10 ft. +/- 0.1% of depth @
 200 kHz
 • 0.10m / 0.30 ft. +/- 0.1% of depth @
 33 kHz
 Depth Range
 • 0.2 – 200m / 0.5 – 600 ft. @ 200
 kHz
 • 0.5 – 1500m / 1.5 – 4500 ft. @ 33
 kHz
 Chart Scales
 • 5,10,20,40,80,100,200,400,800,
 1600 m
 • 15,30,60,120,240,300,600,1200,
 2400,4800 ft.
 Phasing
 • Automatic scale change, 10%,20%,
 30% overlap or Manual
 Sound Velocity
 • 1370 – 1700 m/s
 | • Resolution 1 m/s Transducer Draft Setting
 • 0 – 15m (0 – 50 ft.)
 Depth Display
 • On control PC.
 Clock
 • Internal battery backed time,
 elapsed time, and date clock
 Annotation
 • Internal – date, time, GPS position
 • External – from RS232 port or
 Ethernet.
 Interfaces
 • 2 x RS232 serial ports, baud rate
 selectable 4800-19200.
 • Inputs from external computer,
 motion sensor, sound velocity.
 • Outputs to external computer
 • Ethernet interface
 • Heave – TSS1 and sounder
 sentence
 Blanking
 • 0 to full scale
 Software
 • Echotrac Control supplied
 • ChartView display and logging
 software
 Help
 The function of each parameter and it’s
 minimum and maximum values can be
 displayed.
 Environmental Operating Conditions
 • 0°– 50° C, 5 – 90% relative
 humidity, Non-condensing
 Dimensions
 • 53 cm (20.75”) H x 44cm (17.25”)
 W x 21.5cm (8.5”) D
 |